Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 11.620
Filter
1.
Clin Biomech (Bristol, Avon) ; 114: 106239, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38599132

ABSTRACT

BACKGROUND: The application of expandable titanium-cages has gained widespread use in vertebral body replacement for indications such as burst fractures, tumors and infectious destruction. However, torque forces necessary for a satisfactory expansion of these implants and for subsidence of them into the adjacent vertebrae are unknown within the osteoporotic spine. METHODS: Six fresh-frozen human, osteoporotic, lumbar spines were dorsally instrumented with titanium implants (L2-L4) and a partial corpectomy of L3 was performed. An expandable titanium-cage was inserted ventrally and expanded by both residents and senior surgeons until fixation was deemed sufficient, based on haptic feedback. Torque forces for expansion were measured in Nm. Expansion was then continued until cage subsidence occurred. Torque forces necessary for subsidence were recorded. Strain of the dorsal rods during expansion was measured with strain gauges. FINDINGS: The mean torque force for fixation of cages was 1.17 Nm (0.9 Nm for residents, 1.4 Nm for senior surgeons, p = .06). The mean torque force for subsidence of cages was 3.1 Nm (p = .005). Mean peak strain of the dorsal rods was 970 µm/m during expansion and 1792 µm/m at subsidence of cages (p = .004). INTERPRETATION: The use of expandable titanium-cages for vertebral body replacement seems to be a primarily safe procedure even within the osteoporotic spine as torque forces required for subsidence of cages are nearly three times higher than those needed for fixation. Most of the expansion load is absorbed by straining of the dorsal instrumentation. Rod materials other than titanium may alter the torque forces found in this study.


Subject(s)
Spinal Fusion , Titanium , Humans , Vertebral Body , Torque , Lumbar Vertebrae/surgery , Prostheses and Implants
2.
PLoS One ; 19(4): e0296300, 2024.
Article in English | MEDLINE | ID: mdl-38635518

ABSTRACT

OBJECTIVE: This study aimed to compare the stability and mechanical properties of the double chevron-cut (DCC) and biplanar (BP) distal femoral osteotomy (DFO) techniques, along with analyzing their respective contact surface areas. METHODS: Biomechanical testing was performed using sawbone and 3D modeling techniques to assess axial and torsional stability, torsional stiffness, and maximum torque of both osteotomy configurations. Additionally, 3D models of the sawbone femur were created to calculate and compare the contact surface area of the DCC, BP, and conventional single-plane DFO techniques. RESULTS: Axial stiffness and maximum strength did not significantly differ between the two osteotomy techniques. However, in terms of torsional properties, the DCC technique exhibited superior torsional stiffness compared to the BP group (27 ± 7.7 Nm/° vs. 4.5 ± 1.5 Nm/°, p = 0.008). Although the difference in maximum torque did not reach statistical significance (63 ± 10.6 vs. 56 ± 12.1, p = 0.87), it is noteworthy that the DCC group sawbone model exhibited fracture in the shaft region instead of at the osteotomy site. Therefore, the actual maximum torque of the DCC construct may not be accurately reflected by the numerical values obtained in this study. The contact surface area analysis revealed that the BP configuration had the largest contact surface area, 111% larger than that of the single-plane configuration. but 60% of it relied on the less reliable axial cut. Conversely, the DCC osteotomy offered a 31% larger contact surface area than the single-plane configuration, with both surfaces being weight-bearing. CONCLUSION: The DCC osteotomy exhibited superior mechanical stability, showing improved rotational stiffness and maximum torque when compared to the BP osteotomy. Although the BP osteotomy resulted in a larger contact surface area than the DCC osteotomy, both were larger than the conventional single-plane configuration. In clinical practice, both the DCC and BP techniques should be evaluated based on patient-specific characteristics and surgical goals.


Subject(s)
Fractures, Bone , Osteotomy , Humans , Osteotomy/methods , Femur/surgery , Torque , Lower Extremity , Biomechanical Phenomena
3.
J Mech Behav Biomed Mater ; 154: 106537, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38588632

ABSTRACT

The Advanced System for Implant Stability Testing (ASIST) is a device currently being developed to noninvasively measure implant stability by estimating the mechanical stiffness of the bone-implant interface, which is reported as the ASIST Stability Coefficient (ASC). This study's purpose was to determine whether changes in density, bonding, and drilling technique affect the measured vibration of a dental implant, and whether they can be quantified as a change in the estimated BII stiffness. Stability was also measured using RFA, insertion torque (IT) and the pullout test. Bone-level tapered implants (4.1 mm diameter, 10 mm length) were inserted in polyurethane foam as an artificial bone substitute. Samples were prepared using different bone densities (20, 30, 40 PCF), drilling sequences, and superglue to simulate a bonded implant. Measurements were compared across groups at a significance level of 0.05. The ASC was able to indicate changes in each factor as a change in the interfacial stiffness. IT and pullout force values also showed comparable increases. Furthermore, the relative difference in ISQ values between experimental groups was considerably smaller than the ASC. While future work should be done using biological bone and in-vivo systems, the results of this in-vitro study suggest that modelling of the implant system with a vibration-based approach may provide a noninvasive method of assessing the mechanical stability of the implant.


Subject(s)
Bone Substitutes , Dental Implants , Vibration , Bone and Bones , Bone Density , Torque
4.
J Oral Implantol ; 50(1): 45-49, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38579112

ABSTRACT

The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.


Subject(s)
Dental Implants , Carbon , Titanium , Dental Stress Analysis/methods , Torque , Bone Screws , Dental Abutments
5.
J Oral Implantol ; 50(1): 31-38, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38579114

ABSTRACT

The aim of this study was to evaluate the mechanical behavior of UCLA and Mini-conical abutments for implants with Tri-channel connections regarding torque loss and vertical misfit. Twenty 3-element metal-ceramic fixed partial dentures (FPD) supported by 2 implants were manufactured and divided into 2 groups (n = 10): UCLA (group 1) and Mini-conical Abutments (group 2). The evaluation of torque loss was carried out before and after mechanical cycling, while the vertical fit was evaluated throughout the different stages of manufacturing the prostheses, as well pre- and postcycling (300,000 cycles, 30 N). Statistical analyses of torque loss and vertical misfit were performed using the linear mixed effects model. Both groups showed torque loss after mechanical cycling (P < .05); however, there was no significant percentage differences between them (P = .795). Before cycling, the groups showed a significant difference in terms of vertical misfit values (P < .05); however, this difference was no long observed after cycling (P = .894). Both groups showed torque loss after the cycling test, with no significant difference (P > .05). There was no significant difference in vertical misfit after mechanical cycling; however, in group 1 (UCLA) there was accommodation of the implant-UCLA abutment interface, while group 2 (Mini-conical abutment) did not show changes in the interface with the implant after the test. Both groups behaved similarly regarding the torque loss of the prosthesis retention screws pre- and postmechanical cycling, with greater loss after the test.


Subject(s)
Dental Implants , Torque , Dental Abutments , Dental Stress Analysis , Dental Prosthesis Retention , Dental Implant-Abutment Design
6.
Sensors (Basel) ; 24(6)2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38544265

ABSTRACT

We aimed to determine the feasibility, test-retest reliability and long-term stability of a novel method for assessing the force (torque)-velocity (cadence) profile and maximal dynamic force (MDF) during leg-pedaling using a friction-loaded isoinertial cycle ergometer and a high-precision power-meter device. Fifty-two trained male cyclists completed a progressive loading test up to the one-repetition maximum (1RM) on a cycle ergometer. The MDF was defined as the force attained at the cycle performed with the 1RM-load. To examine the test-retest reliability and long-term stability of torque-cadence values, the progressive test was repeated after 72 h and also after 10 weeks of aerobic and strength training. The participants' MDF averaged 13.4 ± 1.3 N·kg-1, which was attained with an average pedal cadence of 21 ± 3 rpm. Participants' highest power output value was attained with a cadence of 110 ± 16 rpm (52 ± 5% MDF). The relationship between the MDF and cadence proved to be very strong (R2 = 0.978) and independent of the cyclists' MDF (p = 0.66). Cadence values derived from this relationship revealed a very high test-retest repeatability (mean SEM = 4 rpm, 3.3%) and long-term stability (SEM = 3 rpm, 2.3%); despite increases in the MDF following the 10-week period. Our findings support the validity, reliability and long-term stability of this method for the assessment of the torque-cadence profile and MDF in cyclists.


Subject(s)
Bicycling , Ergometry , Humans , Male , Torque , Reproducibility of Results , Foot , Exercise Test/methods
7.
Sci Rep ; 14(1): 7525, 2024 03 29.
Article in English | MEDLINE | ID: mdl-38553519

ABSTRACT

The paper deals with the torques of external muscles acting on the upper ankle joint under weight-bearing conditions and their importance in diagnosing and treating the human foot. Experimental data were collected and calculations were performed. Based on the experiments with the biomechanical model of the foot and upper ankle joint, it was shown how the changes in the force arms of the external muscles of the foot under weight-bearing conditions, change the torque. The real values of muscle forces and torques of the external muscles of the foot were calculated. Taking into account the distance of the lines of muscle action from the axis of rotation of the upper ankle joint the rotational force of the muscles was calculated. The influence of changing the force arm on the rotational efficiency of the muscle balancing the moment of gravity was shown. Knowledge of muscle torque under weight-bearing conditions is crucial for correctly assessing foot biomechanics. It has been shown that torque (gravitational and muscular), not pure force, is crucial when assessing the rotational capacity of the analyzed joint. A change in the approach to diagnostics and treating paresis or weakness of extrinsic foot muscles was proposed through the manipulation of the distance of their action line from the axis of joint rotation.


Subject(s)
Ankle Joint , Tarsal Bones , Humans , Ankle Joint/surgery , Ankle Joint/physiology , Torque , Muscle, Skeletal/physiology , Foot/physiology , Biomechanical Phenomena
10.
Sensors (Basel) ; 24(5)2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38475041

ABSTRACT

The choice of torque curve in lower-limb enhanced exoskeleton robots is a key problem in the control of lower-limb exoskeleton robots. As a human-machine coupled system, mapping from sensor data to joint torque is complex and non-linear, making it difficult to accurately model using mathematical tools. In this research study, the knee torque data of an exoskeleton robot climbing up stairs were obtained using an optical motion-capture system and three-dimensional force-measuring tables, and the inertial measurement unit (IMU) data of the lower limbs of the exoskeleton robot were simultaneously collected. Nonlinear approximations can be learned using machine learning methods. In this research study, a multivariate network model combining CNN and LSTM was used for nonlinear regression forecasting, and a knee joint torque-control model was obtained. Due to delays in mechanical transmission, communication, and the bottom controller, the actual torque curve will lag behind the theoretical curve. In order to compensate for these delays, different time shifts of the torque curve were carried out in the model-training stage to produce different control models. The above model was applied to a lightweight knee exoskeleton robot. The performance of the exoskeleton robot was evaluated using surface electromyography (sEMG) experiments, and the effects of different time-shifting parameters on the performance were compared. During testing, the sEMG activity of the rectus femoris (RF) decreased by 20.87%, while the sEMG activity of the vastus medialis (VM) increased by 17.45%. The experimental results verify the effectiveness of this control model in assisting knee joints in climbing up stairs.


Subject(s)
Exoskeleton Device , Robotics , Humans , Torque , Lower Extremity , Knee Joint
11.
Nat Commun ; 15(1): 2160, 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38461256

ABSTRACT

Rotating magnetic fields enable biomedical microrobots to overcome physiological barriers and promote extravasation and accumulation in tumors. Nevertheless, targeting deeply situated tumors requires suppression of off-target actuation in healthy tissue. Here, we investigate a control strategy for applying spatially selective torque density to microrobots by combining rotating fields with magnetostatic selection fields. Taking magnetotactic bacteria as diffuse torque-based actuators, we numerically model off-target torque suppression, indicating the feasibility of centimeter to millimeter resolution for human applications. We study focal torque application in vitro, observing off-target suppression of actuation-dependent effects such as colonization of bacteria in tumor spheroids. We then design and construct a mouse-scale torque-focusing apparatus capable of maneuvering the focal point. Applying this system to a mouse tumor model increased accumulation of intravenously injected bacteria within tumors receiving focused actuation compared to non-actuated or globally actuated groups. This control scheme combines the advantages of torque-based actuation with spatial targeting.


Subject(s)
Magnetics , Neoplasms , Animals , Humans , Mice , Torque , Physical Phenomena , Magnetic Fields , Bacteria
12.
Clin Oral Investig ; 28(3): 206, 2024 Mar 09.
Article in English | MEDLINE | ID: mdl-38459220

ABSTRACT

OBJECTIVES: This finite element study aimed to simulate maxillary canine movement during anterior teeth retraction. MATERIALS AND METHODS: Three methods of maxillary canine movement including miniscrew sliding with high hooks (MSH), miniscrew sliding with low hooks (MSL), and the traditional sliding method (TS) without using miniscrews were simulated using three-dimensional finite element analysis. The initial displacement of the maxillary canine, the maximum principal stress of the periodontal ligament and the Von Mises stress were calculated. RESULTS: The distolingual tipping movements of the canine were shown in three movement modes. MSH showed a small tendency to lingual tipping movement and a extrusion movement while MSL had the largest lingual inclination. TS demonstrated a tendency toward distolingual torsion displacement. Compressive stress values were mainly concentrated in the range - 0.003 to -0.006 MPa. For tensile stress, the distribution of MSH and MSL was concentrated in the range 0.005 to 0.009 MPa, TS was mainly distributed about 0.003 MPa. Von Mises equivalent stress distribution showed no significant difference. CONCLUSIONS: The loss of tooth torque was inevitable, irrespective of which method was used to close the extraction space. However, miniscrew application and higher hooks reduced the loss of torque and avoided lingual rotation. CLINICAL RELEVANCE: This study shows that miniscrew implants with different hooks can better control the movement of the maxillary canines. The non-invasive nature of the finite element analysis and its good simulation of dental stress and instantaneous motion trend have a clinical advantage in the analysis of tooth movement.


Subject(s)
Cuspid , Tooth Movement Techniques , Bicuspid , Stress, Mechanical , Finite Element Analysis , Torque , Tooth Movement Techniques/methods , Maxilla
13.
PLoS One ; 19(3): e0298401, 2024.
Article in English | MEDLINE | ID: mdl-38512896

ABSTRACT

Researchers conducted an investigation by tornado simulator to study the impact of wind angle on the aerodynamic characteristics of a reduced (1:150) high-speed train model using six-dimensional force/torque sensor. The reduced scale model size can match the relative size relationship between high-speed train and tornado vortex core in real condition. Results show that the wind angle affects the mean value and standard deviation of the force and moment coefficient of the high-speed train at the same radial position. The variations of the mean value and standard deviation of the pitching moment coefficient of the high-speed train carriage model at 60°and 90°are different from that at other wind angles. The variations of the mean value of the pitching moment coefficient of the high-speed train head model at 0°, 15°and 30°are different from that at other wind angles. The variations of the standard deviation of the pitching moment coefficient of the high-speed train head model at 60°,75°and 90°are different from that at other wind angles. This research will help the further study of the operation safety of high-speed train in the event of a tornado impacting a high-speed train network.


Subject(s)
Tornadoes , Wind , Torque
14.
J Strength Cond Res ; 38(4): 671-680, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38513175

ABSTRACT

ABSTRACT: Mongold, SJ, Ricci, AW, Hahn, ME, and Callahan, DM. Skeletal muscle compliance and echogenicity in resistance-trained and nontrained women. J Strength Cond Res 38(4): 671-680, 2024-Noninvasive assessment of muscle mechanical properties in clinical and performance settings tends to rely on manual palpation and emphasizes examination of musculotendinous stiffness. However, measurement standards are highly subjective. The purpose of the study was to compare musculotendinous stiffness in adult women with varying resistance training history while exploring the use of multiple tissue compliance measures. We identified relationships between tissue stiffness and morphology, and tested the hypothesis that combining objective measures of morphology and stiffness would better predict indices of contractile performance. Resistance-trained (RT) women (n = 11) and nontrained (NT) women (n = 10) participated in the study. Muscle echogenicity and morphology were measured using B-mode ultrasonography (US). Vastus lateralis (VL) and patellar tendon (PT) stiffness were measured using digital palpation and US across submaximal isometric contractions. Muscle function was evaluated during maximal voluntary isometric contraction (MVIC) of the knee extensors (KEs). Resistance trained had significantly greater PT stiffness and reduced echogenicity (p < 0.01). Resistance trained also had greater strength per body mass (p < 0.05). Muscle echogenicity was strongly associated with strength and rate of torque development (RTD). Patellar tendon passive stiffness was associated with RTD normalized to MVIC (RTDrel; r = 0.44, p < 0.05). Patellar tendon stiffness was greater in RT young women. No predictive models of muscle function incorporated both stiffness and echogenicity. Because RTDrel is a clinically relevant measure of rehabilitation in athletes and can be predicted by digital palpation, this might represent a practical and objective measure in settings where RTD may not be easy to measure directly.


Subject(s)
Knee Joint , Muscle, Skeletal , Adult , Humans , Female , Muscle, Skeletal/diagnostic imaging , Muscle, Skeletal/physiology , Knee Joint/physiology , Muscle Contraction/physiology , Quadriceps Muscle/physiology , Isometric Contraction/physiology , Ultrasonography , Muscle Strength/physiology , Torque
15.
J Strength Cond Res ; 38(4): 681-686, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38513176

ABSTRACT

ABSTRACT: Takeuchi, K, Nakamura, M, Matsuo, S, Samukawa, M, Yamaguchi, T, and Mizuno, T. Combined effects of static and dynamic stretching on the muscle-tendon unit stiffness and strength of the hamstrings. J Strength Cond Res 38(4): 681-686, 2024-Combined static and dynamic stretching for 30 seconds is frequently used as a part of a warm-up program. However, a stretching method that can both decrease muscle-tendon unit (MTU) stiffness and increase muscle strength has not been developed. The purpose of this study was to examine the combined effects of 30 seconds of static stretching at different intensities (normal-intensity static stretching [NS] and high-intensity static [HS]) and dynamic stretching at different speeds (low-speed dynamic [LD] and high-speed dynamic stretching [HD]) on the MTU stiffness and muscle strength of the hamstrings. Thirteen healthy subjects (9 men and 4 women, 20.9 ± 0.8 years, 169.3 ± 7.2 cm, 61.1 ± 8.2 kg) performed 4 types of interventions (HS-HD, HS-LD, NS-HD, and NS-LD). Range of motion (ROM), passive torque, MTU stiffness, and muscle strength were measured before and immediately after interventions by using an isokinetic dynamometer machine. In all interventions, the ROM and passive torque significantly increased (p < 0.01). Muscle-tendon unit stiffness significantly decreased in HS-HD and HS-LD (both p < 0.01), but there was no significant change in NS-HD (p = 0.30) or NS-LD (p = 0.42). Muscle strength significantly increased after HS-HD (p = 0.02) and NS-LD (p = 0.03), but there was no significant change in HS-LD (p = 0.23) or NS-LD (p = 0.26). The results indicated that using a combination of 30 seconds of high-intensity static stretching and high-speed dynamic stretching can be beneficial for the MTU stiffness and muscle strength of the hamstrings.


Subject(s)
Hamstring Muscles , Muscle Stretching Exercises , Male , Humans , Female , Tendons/physiology , Hamstring Muscles/physiology , Muscle Strength/physiology , Torque , Range of Motion, Articular/physiology , Muscle, Skeletal/physiology
16.
BMC Oral Health ; 24(1): 389, 2024 Mar 26.
Article in English | MEDLINE | ID: mdl-38532413

ABSTRACT

BACKGROUND: While the concept of angled screw channels has gained popularity, there remains a scarcity of research concerning the torque loss and fracture strength of monolithic zirconia restorations with various screw channel angulations when exposed to thermomechanical cycling. This in-vitro study aimed to evaluate the reverse torque value and fracture resistance of one-piece screw-retained hybrid monolithic zirconia restorations with angulated screw channels after thermomechanical cycling. METHODS: One-piece monolithic zirconia restorations, with angulated screw channels set at 0°, 15°, and 25° (n = 6 per angulation) were fabricated and bonded to titanium inserts using a dual-cure adhesive resin cement. These assemblies were then screwed to implant fixtures embedded in acrylic resin using an omnigrip screwdriver, and reverse torque values were recorded before and after thermomechanical cycles. Additionally, fracture modes were assessed subsequent to the application of compressive load. One-way ANOVA and Bonferroni post hoc test were used to compare the groups (α = 0.05). RESULTS: The study groups were significantly different regarding the fracture resistance (P = 0.0015), but only insignificantly different in the mean percentage torque loss (P = 0.4400). Specifically, the fracture resistance of the 15° group was insignificantly higher compared to the 0° group (P = 0.9037), but significantly higher compared to the 25° group (P = 0.0051). Furthermore, the fracture resistance of the 0° group was significantly higher than that of the 25° group (P = 0.0114). CONCLUSIONS: One-piece hybrid monolithic zirconia restorations with angulated screw channels can be considered an acceptable choice for angulated implants in esthetic areas, providing satisfactory fracture strength and torque loss.


Subject(s)
Crowns , Dental Cements , Zirconium , Humans , Torque , Materials Testing , Dental Abutments , Titanium , Bone Screws , Dental Stress Analysis , Dental Restoration Failure
17.
J Musculoskelet Neuronal Interact ; 24(1): 38-46, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38427367

ABSTRACT

BFR) applied during sprint interval training (SIT) on performance and neuromuscular function. METHODS: Fifteen men completed a randomized bout of SIT with CBFR, IBFR, and without BFR (No-BFR), consisting of 2, 30-s maximal sprints on a cycle ergometer with a resistance of 7.5% of body mass. Concentric peak torque (CPT), maximal voluntary isometric contraction (MVIC) torque, and muscle thickness (MT) were measured before and after SIT, including surface electromyography (sEMG) recorded during the strength assessments. Peak and mean revolutions per minute (RPM) were measured during SIT and power output was examined relative to physical working capacity at the fatigue threshold (PWCFT). RESULTS: CPT and MVIC torque decreased from pre-SIT (220.3±47.6 Nm and 355.1±72.5 Nm, respectively) to post-SIT (147.9±27.7 Nm and 252.2±45.5 Nm, respectively, all P<0.05), while MT increased (1.77±0.31 cm to 1.96±0.30 cm). sEMG mean power frequency decreased during CPT (-12.8±10.5%) and MVIC (-8.7±10.2%) muscle actions. %PWCFT was greater during No-BFR (414.2±121.9%) than CBFR (375.9±121.9%). CONCLUSION: SIT with or without BFR induced comparable alterations in neuromuscular fatigue and sprint performance across all conditions, without affecting neuromuscular function.


Subject(s)
High-Intensity Interval Training , Muscle, Skeletal , Humans , Male , Electromyography , Isometric Contraction/physiology , Muscle Fatigue , Muscle, Skeletal/physiology , Regional Blood Flow/physiology , Torque
18.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 59(3): 290-294, 2024 Mar 09.
Article in Chinese | MEDLINE | ID: mdl-38432664

ABSTRACT

Appropriate torque control of anterior teeth is of great significance to obtain ideal orthodontic treatment outcome. Clear aligners are less effective in torque control of anterior teeth due to their special application mode and material properties. Therefore, it is important to investigate how to improve the torque control of anterior teeth by using clear aligners, with the expectation of providing guidance for clinicians. This article discussed the methods to control the torque of anterior teeth by using traditional fixed appliances, the efficiency of clear aligner in controlling the torque of anterior teeth, the difficult points of clear aligner in controlling the torque of anterior teeth and the therapeutic methods to better control the torque of anterior teeth by using clear aligners.


Subject(s)
Orthodontic Appliances, Removable , Tooth Movement Techniques , Humans , Torque , Incisor , Treatment Outcome
19.
Lasers Med Sci ; 39(1): 88, 2024 Mar 08.
Article in English | MEDLINE | ID: mdl-38453765

ABSTRACT

The objective of the study was to investigate the impact of photobiomodulation (PBM) on the paretic upper limb in post-stroke patients with spastic hemiparesis and to understand the potential of PBM as a long-term non-invasive therapy for reducing the side effects caused by spasticity in the hemiparetic upper limb after a stroke. This is a double-blind randomized clinical trial constituted of 27 participants, being Control group (CG = 12 healthy individuals) and PBM group (PBMG = 15 post-stroke individuals). In the CG, the baseline blood lactate (BL) was evaluated, followed by the evaluation of the IC torque of the biceps and triceps muscles, with the isokinetic dynamometer associated with surface electromyography (EMG) and, subsequently, a new measurement of BL. The PBMG received 10 sessions of treatment with PBM (780 nm, Power: 100 mV, Power Density: 3.18 W/cm2, Energy: 4 J, Fluency: 127.4 J/cm2, Time: 40 s per point and 1.280 s total, Spot: 0.0314 cm2, 32 Points: 16 points (brachial biceps) and 16 points (brachial triceps) applied with contact at 90°, Total Energy: 64 J), which in the pre-treatment evaluation measured BL, the visual analogue scale (VAS) of pain; torque and EMG of the same muscles in the IC, subsequently, a new measurement of VAS and BL, and measurement of range of motion (ROM) during the reaching movement. At the conclusion of the ten sessions, all participants underwent a reassessment, wherein all tests originally administered during the initial evaluation were repeated. Subsequently, the data were analyzed using the Shapiro-Wilk normality test. For related data, the paired t-test was used for normal distributions and the Wilcoxon test for non-normal data. For unrelated data, the t test was used for normal distributions and the Mann-Whitney test for non-normal data. Muscle torque was higher for the CG, with a significant difference (CGxPBMG = p < 0.0001). There was no significant difference between the EMG values of the CG in relation to the Pre-PBM phase and with the Post-PBM phase of the PBMG (p > 0.05). On the other hand, there was a 38% reduction in pain reported by hemiparetic patients (p = 0.0127) and a decrease in BL in the PBMG. Post-PBM ROM increased by 46.1% in the elbow extension of the paretic limb. In conclusion, Photobiomodulation (PBM) demonstrated significant improvements in muscle performance, reducing fatigue and pain levels, and enhancing range of motion in post-stroke patients with spastic hemiparesis. These findings support the potential integration of PBM into rehabilitation protocols, but further research and clinical trials are needed to validate and expand upon these promising outcomes.


Subject(s)
Low-Level Light Therapy , Stroke , Humans , Muscle Spasticity/etiology , Muscle Spasticity/radiotherapy , Lactic Acid , Torque , Low-Level Light Therapy/methods , Muscle, Skeletal , Stroke/complications , Stroke/radiotherapy , Electromyography , Upper Extremity , Range of Motion, Articular , Pain/complications , Paresis/radiotherapy , Paresis/complications
20.
J Appl Physiol (1985) ; 136(4): 889-900, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38450425

ABSTRACT

Resistance training at longer muscle lengths induces greater muscle hypertrophy and different neuromuscular functional adaptations than training at shorter muscle lengths. However, the acute time course of recovery of neuromuscular characteristics after resistance exercise at shorter and longer muscle lengths in the quadriceps has never been described. Eight healthy young participants (4 M, 4 F) were randomly assigned to perform four sets of eight maximal isometric contractions at shorter (SL; 50° knee flexion) or longer (LL; 90° knee flexion) muscle lengths in a crossover fashion. During exercise, peak torque (PT), muscle activity [electromyogram (EMG)], and internal muscle forces were assessed. PT and EMG at shorter (PT50, EMG50) and longer (PT90, EMG90) muscle lengths, creatine kinase (CK), and muscle soreness were measured at baseline, immediately after exercise (Post), after 24 h (24 h), and after 48 h (48 h). During exercise, EMG (P = 0.002) and internal muscle forces (P = 0.017) were greater in LL than in SL. During recovery, there was a main effect of exercise angle, with PT50 (P = 0.002), PT90 (P = 0.016), and EMG50 (P = 0.002) all significantly reduced to a greater degree in LL compared with SL. CK and muscle soreness increased after resistance exercise, but there were no differences between SL and LL. The present results suggest that if the preceding isometric resistance exercise is performed at longer muscle lengths, function and muscle activity at shorter and longer muscle lengths are inhibited to a larger degree in the subsequent recovery period. This information can be used by practitioners to manipulate exercise prescription.NEW & NOTEWORTHY Despite the established long-term benefits of training at longer muscle lengths for muscle size and strength, acutely performing resistance exercise at longer muscle lengths may require a longer time course of neuromuscular recovery compared with performing resistance exercises at shorter muscle lengths. Furthermore, there appear to be different joint angle-specific recovery profiles, depending on the muscle length of the preceding exercise.


Subject(s)
Muscle, Skeletal , Resistance Training , Humans , Muscle, Skeletal/physiology , Resistance Training/methods , Myalgia , Electromyography , Quadriceps Muscle , Isometric Contraction/physiology , Creatine Kinase , Torque
SELECTION OF CITATIONS
SEARCH DETAIL
...